Digital Equipment VAXstation 3100 Maintenance Manual page 52

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

STRG-1
7177.0001
Vl.O
E
STRG-1
Status
Status
Troubleshooting 31
controller
status
(0001 • no error)
code for DUAO, not used
code for DUAl, not used
....._ _ _
---'!~Status
code for DUA2,
(1
no error)
(7 •
offline)
(F • STRG-1
error)
' - - - - - - - S t a t u s
code for DUA3, not used
Figure 2-4
AX23 Self-Test Code (STRG-1)
The codes for DUA3. DUAl, and DUAO should be 7s. The code for the
STRG-1 controller should be .0001. The code for DUA2 should be a 1.
If
any
other code
(except 7 (off-line) or F (controller failure)) appears for DUA2,
check
lhe drive for power, make sure the test diskette
is loaded
properly, and
check
the cables for a good collllection. If the code is still not a 1, the
problem
is
either in the drive.
on
the MSC module,
in
the cables. or
on
the
system module.
Refer
to
Table
2-5 to determine
the cause of the
problem. A
complete listing of the
self-test codes are
listed
in
Appendix E.