Utilities 83
Table 3-9 Diskette Formatter Messages
Fomatter Message
VSfmt_STS_ ChkPss
VSfmt_STS_CkRXfmt
VSfmt_STS_RXfmt
VSfmt_QUE_RUsure (DUA# 1/0) 7
VSfrnt_QUE_uniblo (0-2) 7
VSfmt_RES_Succ
VSfrnt_RES_Abtd
VSfmt_RES_ERR #
Explanation
A check pass is being done on the diskette.
The RX23 diskette format is being checked
The RX23 diskette is being formatted.
The fonnauer uses this question as a safety
check.
If
you want to fonnat the diskette
that is indicated by the
#,
enter 1 for yes.
Otherwise, enter any character other than 1
to abort the formatter.
Enter the drive that needs fonnatting. Enter
2 for DUA2 (a 0 is for DUAO, 1 is for
DUAi, and 3 is for DUA3). Any other
character aborts the formatter.
The diskette has been successfully
formatted.
The RX23 fonnatter has been aborted.
The formatter has been stopped because of
the error code indicated by the #. Table 3-10
lists the error codes.
Table 3-1 O T 70 Error Codes for the Diskette Formatter
Code
Description
1
Illegal unit number entered.
3
Error occurred during formatting.
5
Error occurred during the diskette check pass.
6
No diskette loaded in the diskette drive or the diskette is not an RX23
media
3.17 Special Diagnostic Key for Field Service
System Exerciser
The removable media (tape cartridge and diskette) in the maintenance kit must
have a special diagnostic code written on
it
that allows the system exerciser
to write on this media when running in Field Service
mode.
Without this
special
key,
such as on normal customer media, the system exerciser does not