System Exerciser Error Codes 231
(
Table F-3 Serial Line Console Codes (OL00.0000)
Code
Serial Line
0
Keyboard port
1
Video port
2
Printer port
3
Printer port
Table F-4 Each Serial Line's Status/Error Codes (0000.ABCD)
Error Codes
Definition
0
No error is detected for this line.
1
No character is received.
2
Failed to transmit
all
characters or transfer took too long or lost
re,ceive characters.
3
Too many characters received.
4
Character received not equal expected.
5
Parity, framing, or overrun error detected.
6
Baud rate timing error
7
Modem signals not equal expected
8
Overrun error not equal 0
9
Character received not equal expected.
A
Overrun error failed to set.
B
Framing error failed to set.
C
TxRdy bit failed to set.
D
Transmit line received not equal expected.
E
Interrupt request bit ST not set in INT_REQ register.
F
Interrupt request bit ST not cleared in INT_REQ register.