Digital Equipment VAXstation 3100 Maintenance Manual page 241

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

220
Power-Up and Self-Test Error Codes
Table E-15
Binary Mask of Error Flags (0000. VVOO)
Binary Mask
Definition
As Seen on the Screen
0000 0001
Problem is on the system module.
01
0000 0010
Problem is not on the system module.
02
0001 0000
Reset is required to free SCSI bus.
10
0010 0000
Not all selected devices are operating
20
properly.
0100 0000
DMA and interrupts
are
untested.
40
Table E-16 SCSI Controller's Error Codes (0000.00ZZ)
Error Codes
Definition
01
No error
02
Data buffer RAM addressing failure
04
-
Data buffer RAM-byte mask-failure
06
Data buffer data path failure
10
Error in SCSI controller registers during reset
12
Error in
ses1
controller registers-after-reset
20
Unexpected interrupt after reset, IPL
=
lF
22
No interrupt request after reset
24
No interrupt after reset when IPL has been lowered.
26
Interrupt request not cleared following JSR (after reset).
28
Multiple interrupts following reset.
2A
Unknown interrupt following reset.
2C
Wrong interrupt following reset.
30
Phase not bus free at start of test.
40
First attempt to read SCSI controller's registers failed.
42
SCSI controller register address test failed at ini_cmd.
44
SCSI controller register address test failed at mode.
46
SCSI controller register address test failed at tar_cmd.
48
SCSI controller register address test failed at scd_cnt.