Digital Equipment VAXstation 3100 Maintenance Manual page 172

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

(
l
Expansion Boxes 151
When running the system exerciser in Field Service mode, the code for the
RRD40 compact disc expansion box shows that it is removable, but not
writable and that no errors are present (4100.0001 for SCSI ID of 4, 0100.0001
for SCSI
ID
of 0, and 1100.0001 for SCSI
ID
of
1).
Any error code other
than those previously listed
indicates
an error is
most
likely on the
RRD40
box, but never rule out the possibility of an error on the SCSI bus controller
itself.
If
the tests indicate an error on the RRD40 compact disc expansion box,
perform the following steps:
1. Make sure the expansion box has power and is switched on.
2.
Make sure
the
SCSI cable
connects
properly to
the external SCSI port, or
to the previous expansion
box, and
to the
back of the
RRD40
expansion
box.
3. Make sure the SCSI terminator installs on the unused connector on the
back of the box or that the cable secures the next daisy-chained box.
4. Run the tests again.
5.
If
the problem returns, disconnect
the
RRD40 expansion box
from the
daisy chain
or
from the SCSI port
if no other boxes
are connected.
Install
the SCSI terminator on the external SCSI port, and make sure the last
expansion box properly terminates. Run self-test (TEST 6).
6.
If
the status code is not FFFFFF05 for the address ID of the RRD40
expansion box (normally address ID 4), check the SCSI address IDs of all
drives
on
the bus for proper
settings.
If
the address IDs are set correctly,
replace the MSC module.
7.
If
the status code is FFFFFF05, check the address ID switch on the back
of the
RRD40
expansion box
to make
sure it
is set properly. Refer to
Figure
~
17 for
proper SCSI
ID switch
settings.
8.
If
the address ID is set properly, fault in the RRD40 expansion
box
or the SCSI cabling exists. Check the cabling for proper connections,
terminations, and damaged pins.
If
the cabling is good, replace the RRD40
expansion box .
9.
If
a problem still exists, replace the MSC module in the system box.