Sign In
Upload
Manuals
Brands
Digital Equipment Manuals
Desktop
VAXft Systems 810
Digital Equipment VAXft Systems 810 Manuals
Manuals and User Guides for Digital Equipment VAXft Systems 810. We have
1
Digital Equipment VAXft Systems 810 manual available for free PDF download: Service Information
Digital Equipment VAXft Systems 810 Service Information (236 pages)
Brand:
Digital Equipment
| Category:
Desktop
| Size: 2 MB
Table of Contents
Service Information
1
Table of Contents
5
1.1 in this Chapter
15
Cabinet Layout, Front View
16
Key to Figure 1-1, Cabinet Layout, Front View
17
Cabinet Layout, Rear View
18
Key to Figure 1-2, Cabinet Layout, Rear View
19
Zone Control Panel
20
Key to Figure 1-3, Zone Control Panel
21
Power Module Controls and Indicators
22
Power Modules
22
Domestic and International Power Distribution Boxes
23
Key to Figure 1-4, Power Module Controls and Indicators
23
Key to Figure 1-5, Domestic Power Distribution Box
24
Domestic Power Distribution Box
24
Key to Figure 1-6, International Power Distribution Box
25
International Power Distribution Box
25
In this Chapter
27
Key to Figure 2-1, System Components
28
System Components
28
Console Operating Modes
29
Function of the Console Components
29
Entering CIO Mode
30
Console Operating Modes
30
Console Control Characters and Function Keys
31
2.5 Console Command Language Syntax
32
Bootstrap Procedures
33
Boot Procedure
33
CIO Mode Console Commands
35
Qualifiers for BOOT
35
VMB Program /R5:<Flag> Values
36
Qualifier for CLEAR
36
Continue
37
Qualifiers for DEPOSIT
37
Indirect Addressing
38
Examine
39
Qualifiers for DUP
39
Qualifiers for EXAMINE
40
Qualifiers for FIND
41
INITIALIZE Steps
42
Repeat
43
SET Variables and Values
43
SHOW Variables
44
Set Boot
44
Start
45
Test
46
Transfer)
47
Qualifier for Z
48
In this Chapter
49
Before Stopping a Zone
50
After a Zone Is Repaired
50
Operating Rules and Cautions
50
Before Leaving the Site
51
3.4 General Troubleshooting Procedure
52
Module Fault Leds
54
Power System Overview
55
Key to Figure 3-1, Module Fault Leds
55
Power System Block Diagram (1 of 2)
56
Power System Block Diagram (2 of 2)
57
Power System Functional Summary
58
Power System Maintenance
60
System DC Voltage Summary
60
Key to Figure 3-4, Power Module Controls and Indicators
61
Power Module Controls and Indicators
61
Fan, LDC, Temperature Error Codes
63
FEU Error Codes
64
PSC Error Codes
64
DC to DC Converter Error Codes
66
Device Status and Fault Indicators
67
RF35 Disk Drawer Controls and Indicators
68
SF35 Operator Control Panel
69
SF35 Storage Array
69
SF35 Operator Control Panel Description
70
SF35 Rear Panel Fault Indicator
71
SF35 Rear Panel Controls and Indicator
71
Location of SF73 Storage Array Leds and Switchpacks
72
SF73 Front Panel Controls and Indicators
72
Rear of the SF73 Storage Array
73
TF85C Cartridge Tape Drive
74
TF85C Tape Drive Problems
74
TF857 Tape Loader
75
TF85C Cartridge Tape Drive Indicators
75
TF857 Operator Control Panel
76
TF857 OCP Controls and Indicators
76
ROM-Based Diagnostics
77
Test
78
CPU ROM-Based Diagnostic Descriptions
79
O ROM-Based Diagnostics
82
I/O ROM-Based Diagnostic Descriptions
82
In this Chapter
85
Hardware Error Handling Flowchart
86
Basic Error Isolation and Handling
86
EHS Error Notification
86
EHS Structure
87
Error Handling Flowchart Definitions
87
EHS Architectural Position
88
System Operating Modes
88
Error Types
89
VAXELN Error Handling
94
VAXELN Error Classes
95
Field Replaceable Units (Frus)
96
System Frus
96
Deconfiguration
97
ATM Deconfiguration Actions
97
CPU Deconfiguration Actions
98
CPU Module and Memory
98
I/O Expansion Module Deconfiguration Actions
99
Interface Module Deconfiguration Actions
99
Zone Deconfiguration Actions
100
Cross-Link Cable Deconfiguration Actions
100
Application of Thresholds
101
FRU Thresholds
101
Openvms Error Log Format
103
Openvms Error Log Sizes
103
Fault Summary Block Entry Descriptions
104
FRU Information
106
FRU Information Block Entry Descriptions
107
Deconfiguration Information Block
108
Deconfiguration Information Block Entry Descriptions
108
Threshold Information Block Entry Descriptions
110
Fault Data
111
System Register Entry Descriptions
112
End Actions
112
End Actions Register Descriptions
113
End Action Timeouts
113
End Action Timeout Block Entry Description
114
VAXELN Detected Error Block Entry Descriptions
114
VAXELN Detected Errors
114
Software Detected Errors
118
End Action Timeout Block
114
VAXELN Detected Error Block
114
Software Detected Error Block Entry Descriptions
119
Unsynchable Events
120
Software Detected Error Block
119
Unsynchable Event Block Entry Descriptions
121
Unsynchable Event Block
121
Module NVRAM Status and LED Indicators
122
Module ID NVRAM/DCB Status Codes
123
FTSS Event Reporting Interface
124
Deconfiguration Messages
133
Firmware Interfaces
134
System Reset Action Codes
135
System Resets
135
System Reset Reason Codes
136
Error Handler Reset Reasons
136
CCA Fields
137
Firmware and Openvms Interface Data Structures
138
I/O Reset Action Code Description
138
I/O Reset Reason Code Descriptions
138
Firmware and Openvms Data Structure Memory Map
138
Console Communications Area
139
Duplex Compatibility Test
141
CCA Component Descriptions
139
Duplex Compatibility Test Failure Codes
142
Dispatch Block Structure
143
Dispatch Block Description
143
Dispatch Block Components
144
BPB Components
144
Boot Parameter Block Description
144
Device Configuration Block
145
BPB Entry Components
145
DCB Components
145
DCB Entry Components
145
Sub-Device Configuration Blocks
147
Subdcb Links to DCB
148
CPU Module Subdcb
148
Page Frame Number Bitmap
149
CPU Subdcb Components
149
CPU Subdcb Entry Components
149
Error Log Analysis
150
Fault Summary Block
150
FRU Information Block
150
CPU/MEM Fault End Action Error Log Entry
153
CPU or Zone Unsynchable Error Log Entry
156
Fault Data Block
156
Domestic Power Distribution Box
159
International Power Distribution Box
159
In this Chapter
159
Model 810 Frus
159
Before You Begin
161
Handling Frus
162
Verifying Zone Shutdown
163
FRU Removal and Replacement
164
CPU Module and ATM Module Removal Procedure
165
CPU Module and ATM Module Locations
165
Simms
166
SIMM Removal Procedure
166
SIMM Locations
166
Mmbs
167
MMB Removal Procedure
167
MMB Locations
167
Fan and FCSB
168
Fan Location
168
Fan and FCSB Removal Procedure
169
FCSB Location
169
RF35 Disk Drive Removal and Replacement
170
RF35 Disk Drive Location
170
RF35 Disk Drive Removal Procedure
171
DSSI Disk Drawer Removal Procedure
172
Zone Control Panel
173
Zone Control Panel Removal Procedure
173
FEU, 3.3V Regulator, 5V Regulator, and PSC Locations
174
FEU, 3.3V Regulator, 5V Regulator, and PSC Removal Procedure
175
Cross-Link Assembly
176
Cross-Link Assembly Removal Procedure
177
Module Extraction Tool
177
Console Extender Module Location
178
Console Extender Module Removal Procedure
179
Console Extender Module Layout
179
DSSI Extender Module Locations
180
DSSI Extender Module Removal Procedure
181
CAMP Module Locations
182
CAMP Module Removal Procedure
183
DSSI Interface Module (DIM)
184
DIM Location
184
DIM Removal Procedure
185
DIM Removal
185
Ethernet Interface Module (EIM)
186
EIM Removal
186
DSSI Cable Removal and Replacement
187
EIM Removal Procedure
187
DSSI Cable Removal Procedure
187
TF85C-BA Tape Drive, Rear View
188
TF85C-BA Tape Drive Removal Procedure
189
TF85C-BA Tape Drive Removal
189
SF73 Disk Drive, Rear View
190
SF73 Disk Drive, Front View
191
SF73 Disk Drive Enclosure Removal Procedure
191
SF73 Disk Drive Enclosure Removal
192
SF73 Disk ISE Removal
193
SF35 Storage Array, Rear View
194
SF35 Storage Array, Front View
195
SF35 Disk ISE Removal
196
SF35 Storage Array Removal Procedure
196
TF857-CA Tape Drive, Rear View
197
Loosening the Shipping Restraint Screw
198
TF857-CA Tape Drive Removal Procedure
198
Setting the TF857 Tape Loader Node ID
199
Power Distribution Box
200
Power Distribution Box Removal Procedure
201
Managing Integrated Storage Elements
203
6.2 Loading the DUP Driver
203
6.3 Using VMS DUP
203
6.4 Using the Server Setup Switch
204
6.5 Assigning DSSI Unit Numbers
204
PARAMS Commands
204
Switches for Disabling the MSCP
204
6.6 Warm Swapping an ISE
205
Vaxft Model 810 Front View
205
Vaxft Model 810 Rear View
206
6.6.1 Setting ISE Parameters
207
ISE Parameters
207
6.6.2 ISE Removal
209
6.6.3 ISE Replacement
210
Disabling the MSCP
211
6.6.4 Installing an ISE in a Running System
213
Processor Halt Code Definitions
217
Processor Halt Codes
217
Console Halt Codes
217
Error Register Descriptions
217
I/O Physical Address Space
217
System Control Block Description
217
A.1 in this Appendix
217
Processor Halt Reason Code Definitions
218
Console Halt Reason Code Definitions
219
Xlink Mode Coding
220
System Fault Register
220
JXD System Error Address Register
223
A.4.2 System Error Address (SYSADR) Register
223
JXD DMA Error Address Register
223
A.4.3 DMA Error Address (DMAADR) Register
223
A.4.4 Reset Reason 0013 Fault Analysis
224
I/O Physical Address Space
225
Code Field Definition
226
System Control Block Base Register
226
System Control Block Vector Format
226
SCB Layout
227
B.1 in this Appendix
229
Individual ISE Parameter Worksheets
229
B.3 ISE Zone Parameter Worksheets
231
Advertisement
Advertisement
Related Products
Digital Equipment 800S
Digital Equipment Starion 800i
Digital Equipment 8504P
Digital Equipment 8504FP
Digital Equipment 8508F
Digital Equipment 8508
Digital Equipment 8504
Digital Equipment 8508C
Digital Equipment SWXTA-LA 8-GB
Digital Equipment AlphaServer 8400 5/440
Digital Equipment Categories
Desktop
Server
Computer Hardware
Printer
Storage
More Digital Equipment Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL