TEST 50
KA42-A Vl.0
ID 08-00-2B-02-CF-A4
MONO
0000.0001
CLK
0000.0001
NVR
0000.0001
DZ
0000.0001
Testing 9
00000001 00000001 00000001 00000001 00000001 000012AO
MEM
0008.0001
00800000
MM
0000.0001
FP
0000.0001
IT
0000.0001
STRG-1
7177.0001 Vl.O
00000000 00000000 00000960 00000000
SCSI-A
0808.0001 Vl.O
FFFFFFOS FFFFFFOS FFFFFFOS 00000001 FFFFFFOS FFFFFFOS FFFFFF03
SYS
0000.0000
8PLN
0000.0001 Vl.O
NI
0000.0001
>>>
Figure 1-4 Model 30 System Configuration Table with RX23 Drive
Any code in the configuration table other than 0000.0001 on the MONO, DZ,
MM, FP, IT, or SYS devices indicates a hard error and the system module
must be replaced
for proper operation of
the system.
The
other devices
such
as CLK, NVR,
MEM, STRG-1,
SCSI-A,
SCSI-B,
and
NI
may have
a code
other than (0000.0001) and may still
operate
normally. Go to the device's
troubleshooting section in Chapter 2 to determine whether
or not
the device's
code indicates a fault or a status for the device. Refer to Section 3.1 if you
need an explanation of bow
to
read
the
configuration table.
Refer to Appendix
E if you need a detailed listing of
the
power-up error codes.
Since a 'l could indicate status information, some common power-up status
messages are defined as follows:
Clock not set -
'l E 0040 0000.0005
This message indicates that the system clock has not been set. Setting the
clock is part
of
the operating system software installation and cannot be
set while in console mode. Once the clock is set, this code will be cleared
the next time the clock circuits are tested.
Low battery -
'l D 0050 0000.0005