System Exercleer Error Codes 233
Table F-5 (Cont.) Fatal Device's Error Codes (OOFF.ABCD)
Error Codes
Definition
0017
Unexpected receive interrupt occuned with interrupt mask bit
cleared.
Error codes for BASIC INTERRUPT TEST
0018
INT_MSK register bit ST failed to set.
0019
Failed to receive a transmit interrupt.
OOlA
Transmit interrupt occuned with INT_MSK bit ST cleared.
OOlB
INT_MSK register bit SR failed to set.
001 C
Failed to receive a receive interrupt.
0010
Receive interrupt occurred with INT_MSK bit SR cleared
Error codes in BREAK_DBTECT_TEST
OOIE
TROY failed to set after setting line enable for line in TCR register.
Error codes in OUTPTR CHAR_.POLLBD
OOlF
TROY failed to set in allotted time.
F.3 System Memory (MEM)
Error code format: XXXX.OOYZ
Where XXXX indicates the status code and Y and Z indicate the type of error.
Table
F~
lists the codes.
When there is no error, the status code (XXXX.0001) indicates the number of
pages tested at the time of the report. Otherwise, the status code indicates the
failing test.