232
System Exerciser Error Codes
Table F-5
Fatal Device's Error Codes (OOFF.ABCD)
Error Codes
Definition
0001
Interrupt mask register, INT_MSK, register bits ST or SR stuck at 1
Error Codes in READ WRITE REGISTER TEST
0002
Master clear failed to reset DZQ.
0003
CSR register: expected %xl028
0004
CSR register failed to
clear.
0005
TCR register: expected %xOFOF
0006
TCR register failed to clear.
Error Codes in INTERRUPT BITS TEST
0007
TROY bit in CSR stuck at
1.
0008
TROY bit in CSR failed to set.
0009
OOOA
OOOB
-
-OOOG-
0000
OOOE
OOOF
0010
0011
0012
0013
0014
0015
0016
TROY bit in CSR failed to clear after transmitting a character.
TRDY bit in CSR failed to set
a..~er
tra.nsmifting a character.
RDONE bit failed to set after transmitting character in internal
loopback mode.
-SR-bit-in-JNT=:,REQ-register-not-set-by-RDON.t;.-
SR bit in INT_REG register not cleared by writing bit in INT_CLR
register.
Character received: 0 or line number not equal expected
Data valid bit not set in word read.
Silo alarm enable failed to set L'l CSR.
Silo alarm failed to set after transmitting 16 characters in internal
loopback.
RDONE not set after 16 characters received.
SR bit in INT_REQ register not set by silo alarm.
Silo alarm failed to clear after reading a character from
silo.
Master clear failed to reset the
DZQ.
Unexpected transmit interrupt occurred with interrupt mask bit
cleared.