222
Power-Up and Self-Test Error Codes
Table E-16 (Cont.) SCSI Controller's Error Codes (0000.00ZZ)
Error Codes
Deftnltton
A2
Tuneout waiting for bus free interrupt.
A4
ISR not hit following bus
free.
A6
Interrupt request int_req(sc) not cleared following ISR after bus free.
AS
SCSI bus status(intreq) not set following bus free.
AA
Multiple interrupts from bus free
AC
Unknown interrupt from bus free
AE
Wrong interrupt from bus free
BO
SCSI bus busy during interrupt test - no test done.
B2
Tuneout waiting for parity interrupt.
B4
ISR not hit following parity.
B6
Interrupt request int_req(SC) not cleared following ISR after parity.
-
as-
-
-scsrbus
status(intreq) not
set
ffillowing parify.
BA
Multiple interrupts from parity
BC
Unknown interrupt from parity
BE
Wrong interrupt ffom parity
CO
Phase is not bus free before arbitration.
C2
Ini_cmd(aip) bit failed to set.
C4
Lost arbitration (first check of ini_cmd(la))
C6
Higher priority device in bus
CS
Lost arbitration (second check of ini_cmd(la))
DO
Not all selected targets tested satisfactory.