64 Utllltles
TEST 50
M.42-A Vl.O
ID 08-00-2B-02-CF-A4
MONO
0000.0001
CLK
0000.0001
NVR
0000.0001
DZ
0000.0001
00000001 00000001 00000001 00000001 00000001 000012AO
MEM
0008.0001
00800000
MM
0000.0001
FP
0000.0001
IT
0000.0001
SCSI-A
0808.0001 Vl.O
FFFFFFOS FFFFFFOS FFFFFFOS 00000001 FFFFFFOS FFFFFFOS FFFFFF03 ..•
SCSI-B
COC0.0001 Vl.O
FFFFFFOS FFFFFFOS FFFFFFOS 00000001 FFFFFFOS 01000001 FFFFFF03
•••
SYS
0000.0001
8PLN
0000.0001 Vl.O
NI
0000.0001
>>>
Figure 3-1
Example of the Configuration Table
NOTE
The 8PLN code will show a soft error (xxxx.0213) when using a
monochrome monitor without the 75 ohm terminators installed on the
video cable's red and blue cables.
The first line contains the CPU and the ROM version (KA42-A Vl.0).
The second line contains the Ethernet hardware address
(in
this example it
is ID 08-00-2B-02-CF-A4). The rest of the display contains the status/error
codes for the devices iosta1led on the system. The configuration table is built
during power-up testing and the codes are the result of the self-test and power-
up tesls. This configuration table
is
the only place the
results
of self-test
are
indicated. It is updated. every time you run self-test. Additional codes on
the DZ, MEM, STRG-1, SCSI-A, and SCSI-B give a more detailed status on
these devices as listed. in the following section.