Digital Equipment VAXstation 3100 Maintenance Manual page 105

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

84
Utilities
do write testing on the removable media devices. This safety feature prevents
accidentally destroying the customers programed diskettes or tapes.
There
are two utilities that create these special keys. TEST 72 creates a
special key on the diskette and TEST 73 creates a special key on the tape.
The diskette and tape in the maintenance kit must be initialized with these
special diagnostic keys before they can be used. The tape must be initialized
every time you use it with the Field Service mode system exerciser, because the
special diagnostic key on the tape is destroyed once the
exerciser
recognizes
the key. The special diagnostic key on the diskette is not destroyed when it
is used.
Figure 3-16 shows a successful example of creating a special-key diskette.
>>>
TEST 72
KA42-A RXmker
VSfmk_QUE_MEOtyp (l=RX23)
?
1
VSfmk_QUE_RUsure (DUA2 1/0)
?
1
<---
Enter media type.
<---
Enter 1 for yes,
0
for
no.
VSfmk RES SUCC
<---
Keyed successfully.
>>>
Figure 3-16
Example of Creating the Special Key on a Diskette
Figure 3-17
shows a successful example of creating a special-key tape
cartridge.
If
any errors occur while running TEST 72 or TEST 73, make sure
the
drive is
on-line
and
operating
properly and run the
special-key
command
again. Also,
make
sure the tape is
not
write-protected.