Example Of System Exerciser Display For The Rx23 - Digital Equipment VAXstation 3100 Maintenance Manual

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

Troubleshooting 33
1 0090
STRG-1 2000.0001
2500.0001
2
0 00:02:09.47
Drive status (0001 • no error)
Drive error count (00
no error)
Writable/formatted indication
Drive Indicator (2 • DUA2)
Figure 2-5 Example of System Exerciser Display for the RX23
There is one line for the controller status and one line for the RX23 drive.
A drive
that.
is not installed (such as DUAO, DUAi, and DUA3) or is off-
line is not listed in the display. For example, no diskette in the RX23 or an
unformatted diskette in the RX23 labels DUA2 as off-line and no display for
DUA2 is listed. If there are any question marks on the STRG-1 controller's
line, replace the MSC module.
If
there are any question marks on the RX23's
line, a hard error in the RX23 is detected or an error in the STRG-1 controller
is detected. You must replace one or both to
fix
the problem. Question marks
(?
or
??)
for the RX23 may indicate bad media on the diskette.
Table 2-6 and Table 2-7 describe the meaning of the codes for the STRG-ls
system exerciser. Table 2-6 lists the STRG-1 controller's codes (first line)
and Table b-7 lists the RX23's codes. Appendix F contains a complete listing
of the system exerciser error codes.
Table
2-6
STRG-1 Controller System Exerciser Codes
Codes
X000.0001
OX00.0001
OOXX.0001
0000.XXXl
Explanation of Codes
Indicates the drive used for the data transfer test.
0
=
DUAO, 1 = DUAl, 2 = DUA2, 3 =DUA3, and F • no data
transfer test.
Data transfer status (0 = no error).
Indicates the number of errors detected during the data transfer test
(00 = no
error).
STR0-1 Controller status (000 =no error).