Troubleshooting 59
Table 2-15 lists the system module power connector voltages.
Table 2-15 System Module Power Connector Voltages
Pin Number
Voltage
Tolerance
1
- 12.1 Vdc
5%
2
Ground
3
Ground
4
Ground
5
+
5.1 Vdc
5%
6
+
5.1 Vdc
5%
7
+
3.5 to
+
5.25 Vdc
8
+
5.1 Vdc
5%
9
+
12.1 Vdc
5%
10
+
5.1 Vdc
5%
11
Ground
12
Ground
13
1
-
9 Vdc
5%
14
2 -
9 Vdc return
1
Measurement made with negative lead connected to pin 14
2
0round for the - 9 Vdc supply (an isolated supply)
Table 2-16 lists the drive power connector voltages.
Table 2-16 Drive Power Connector Voltages
Pin Number
Voltage
Tolerance
1
+
12.1 Vdc
5%
2
Ground
3
Ground
4
+
5.1 Vdc
5%