Digital Equipment VAXstation 3100 Maintenance Manual page 155

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

134
Expansion Boxes
Figure 6-2 and Figure 6-3 show how the RZ55 expansion box connects to
the system box.
EXTERNAL
SOl!ll CABLE
RZH
TERMINATOR
EXPANSION
-
----"t<--H-----1¥++------
BOX
Figure 6-2 RZ55 Expansion Box Connection
MLO~OOOl81
UA-X1171·111
------------"ECON.0-fll'.5"----------------------------~
EXPANSION
BOX
-----~
TERMINATOR
------~
EXPANSION
BOX
CABLE
- -
-- 1 -·m"
Figure 6-3 RZSS Expansion Boxes Daisy Chained
MLO·OOOllS
MA·X11715-811
One exception is when the TK50Z-FA expansion box connects to the SCSI port
{expansion box
without a SCSI
ID switch
on the back of the
box,
the TK50Z-
GA
has
the switch).
The
TK.'50Z-FA expansion box
must
be
disconnected
and the RZ55 expansion box must be connected between the external SCSI
port
and
the
TK50Z-FA expansion
box. The
TKSOZ-FA
expansion box has
termination
resistors
installed
inside
its box.
The TK50Z-FA expansion
box
must
be
installed at the end of the daisy chain. The TK50Z-GA expansion box
does not have the resistors installed and can be anywhere in the daisy chain.