Test B - Mem - Memory - Digital Equipment VAXstation 3100 Maintenance Manual

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

26 Troubleshooting
Table 2-2 DZ Port Assignments
Port
VMS Mnemonic
ULTRIX Mnemonic
Keyboard
ITAO
Mouse/tablet
ITAi
Communication
ITA2
/dev/tty02
Printer
ITA3
/dev/tty03
2.7 TEST B -
MEM
- Memory
-
The memory
diagnostics
test all of the main memory
in the
system including
any memory option modules installed. Therefore
any
error for the memory
must be deciphered to determine which module contains the error. There may
be more than one module containing the
error.
_S
~
eJf-t~t
and the
system
exerciser are used to troubleshoot the memory circuits.
Enter TEST B to run
self-test.
Then enter TES
50 to ::;ee the results or enter
TEST 80000106 and Bat the prompt to run the Field Service system
exerciser
on just
the memory circuits (loopback required on communication port).
--A-
code-oi-OOXXTOOOi-(seif~tesi)_nexi_to_th~__j
' .IBM
mnemonic
indicates no
errors
det~ted
with
the memory circuits
(the
XX is the total amount of
memory installed in the system (in hexadecimal)). If an error is detected,
refer
to
Section 2.7
.1 to
determine which module, the system module or one
of the memory modules, needs to be replaced.
A code of
OXXX.0001
(system exerciser) next to the MEM mnemonic
indicates no errors
detected
with the memory circuits (the
XXX
is the number
of pages of
memory
tested during
the last
pass of the
exerciser
(1
page= 512
bytes)).
Table
2-
3
lists
the MEM system exerciser error codes and lists which
module needs
to be
replaced
when
an error is detected.

Advertisement

Table of Contents
loading