Digital Equipment VAXstation 3100 Maintenance Manual page 227

Hide thumbs Also See for VAXstation 3100:
Table of Contents

Advertisement

206
Console Messages and Explanations
Table C-1 (Cont.) Console Error Messages
Message
lB PSLEXC7
lD PSL REIS
lE PSL REI6
lF PSL REI7
20TOYERR
21 CORRPTN
22 ILL REF
23 ILL CMD
24 INV DOT
25 LTL
26 ILL ADR
1.7 VAL TOO LRG
28 SWCONF
29UNKSW
2A UNKSYM
2B
CHK:S:M:
2CHLTED
2D FNDERR
2ETMOUT
2F !\IBM ERR
30 UNXINT
40 NOSUCHDEV
Explanation
PSL26:24
=
7 on interrupt or exception
PSL26:24
=
5 on rei
PSL26:24
=
6 on rei
PSL26:24
=
7 on rei
Time-of-year (TOY) clock failure.
The console database is corrupted. The console simulates
a power-up sequence and rebuilds its database.
The requested reference violates virtual memory
protection and tl1e address is not mapped.
Either
the
reference is not valid in the specified address space or the
value is not valid in the specified destination.
The command string cannot be
parsed.
A number has an invalid digit.
The command is too large for the console to buffer.
The specified address is not in the address space.
The specified value does not fit in the
destination.
Conflicting switches. For example, an
EXAMINE
command that specifies two different data
sires.
The switch is not recognized.
The examine or deposit symbolic address is not
recognized.
Either the whole tr>..nsfer (X} command or just the <data>
portion of the TRANSFER command is not valid.
The operator entered the HALT command.
A FIND command failed to find either the RPB or 64
Kbytes of good memory.
Data failed to arrive in the expected time during a transfer
(X) command.
Parity or other memory error detected.
An unexpected interrupt or exception occurred.
V:MB message: No bootable device found.