VS 3100 (Model 30) System
6. Push the IIDA back against the rubber stops, then lift up the front of the
IIDA and remove it from the frame.
7. Slide the IIDA into the rubber stops on the new drive module/frame.
8. Screw in the two new screws supplied.
9. Position the jumpers on the new drive module to the same position as they
were on the old drive module you just removed (Figure 4-12).
CONNl!CTOR TO
HDA MODULI!
0
D
D
D
D
D
D
D
0
SIGNAL
CONN•CTOA
\
0
D
D
i:ll
!
1
H
u
D
DI "
0
POWl!R
CONHl!:CTOA
"-=i
y.-,.xo7H·H
Figure 4-12
RZ22 and RZ23 SCSI Address Jumpers
4.2.5 TZ30 Tape Drive Removal
1. Remove the system box cover (Section 4.2.1 ).
2. Remove the drive mounting panel (Section 4.2.2).
3. Disconnect the SCSI bus cable from the back of the TZ30.
4. Tum the drive mounting panel over and remove the four screws from the
TZ30. Support the TZ30 with one hand when you remove the last screw.