CHAPTER 7 INTERRUPTION/EXCEPTION PROCESSING FUNCTION

7.4.3 Exception status flag (EP)

The EP flag is bit 6 of the PSW, and is a status flag used to indicate that exception processing is in progress. It is
set when an exception occurs.
31
PSW
0
0
0
0
0
Bit Position
Bit Name
6
EP
290
0
0
0
0
0
0
0
0
0
0
0
Exception Pending
Shows that exception processing is in progress.
0: Exception processing not in progress.
1: Exception processing in progress.
User's Manual U14359EJ4V0UM