CHAPTER 10 TIMER/COUNTER FUNCTION (REAL-TIME PULSE UNIT)
Figure 10-14. TMD0 Compare Operation Example (2/2)
(b) When CMD0 is set to 0
Count clock
Count up
TMD0 clear
Clear
FFFFH
0
0
1
TMD0
0
CMD0
Match detected
(INTCMD0)
Overflow
Interval time = (FFFFH + 2) × (Count clock cycle)
Remark
356