NEC V850E/MA1 User Manual page 430

32-bit single-chip microcontroller
Hide thumbs Also See for V850E/MA1:
Table of Contents

Advertisement

Figure 12-14. Example of 4-Trigger Mode Operation (Timer Trigger Scan: 4 Triggers)
INTM000
INTM001
INTM010
INTM011
(1)
The ADCE bit of ADM0 is set to 1 (enable)
(2)
The CCC01 compare is generated (random)
(3)
ANI1 is A/D converted
(4)
The conversion result is stored in ADCR1
(5)
The CCC11 compare is generated (random)
(6)
ANI3 is A/D converted
(7)
The conversion result is stored in ADCR3
Caution INTM0nn cannot be used as a trigger for the analog inputs enclosed in the broken lines
TM0nn (n = 0, 1). When a setting is made to scan ANI0 to ANI7, ANI4 to ANI7 are
converted in A/D trigger mode (see (b) below).
INTM000
INTM001
INTM010
INTM011
(1) to (13)
Same as (a)
(14) ANI4 is A/D converted
(15) The conversion result is stored in ADCR4
(16) ANI5 is A/D converted
(17) The conversion result is stored in ADCR5
430
CHAPTER 12
(a) Setting when scanning ANI0 to ANI3
random
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
(b) Setting when scanning ANI0 to ANI7
random
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
User's Manual U14359EJ4V0UM
A/D CONVERTER
A/D converter
(8)
The CCC00 compare is generated (random)
(9)
ANI0 is A/D converted
(10) The conversion result is stored in ADCR0
(11) The CCC10 compare is generated (random)
(12) ANI2 is A/D converted
(13) The conversion result is stored in ADCR2
(14) The INTAD interrupt is generated
A/D converter
(18) ANI6 is A/D converted
(19) The conversion result is stored in ADCR6
(20) ANI7 is A/D converted
(21) The conversion result is stored in ADCR7
(22) The INTAD interrupt is generated
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7

Advertisement

Table of Contents
loading

Table of Contents