HPE ProLiant DL385 Gen11 Maintenance And Service Manual page 246

Table of Contents

Advertisement

b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Do one of the following:
a. Remove the air baffle .
b. Remove the midplane drive cage .
9. Remove the fan cage.
10. Disconnect all cables from the expansion cards, riser boards, and the system board.
11. Remove all riser cages
12. If installed, remove the following components:
Type-o storage controller
Chassis intrusion detection switch
Energy pack
OCP NIC 3.0 adapter
Serial port cable
13. If the serial port cable is not installed, remove the hex screws from the serial port slot.
14. If installed, remove the cable guards .
15. Remove all DIMMs.
16. Allow all internal system components to cool before continuing.
17. Remove the heatsink:
CAUTION:
CAUTION:
To prevent mechanical damage or depositing oil on your hands or other contaminant to the heatsink contact surface,
hold the heatsink only by the edge of its base plate. Do not touch the heatsink fins.
a. Review the heatsink screw numbering on the heatsink label.
HPE ProLiant DL385 Gen11 Server Maintenance and Service Guide