b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack .
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Remove the fan cage.
10. Remove the midwall bracket .
11. Remove the drive backplane bracket .
12. Disconnect the cables from the 2 SFF side-by-side drive backplane.
13. Remove the front 2 SFF side-by-side drive cage:
a. Remove the drive cage screws (callout 1).
b. Remove the front 2 SFF side-by-side drive cage from the server (callout 2).
14. Remove the 2 SFF side-by-side drive backplane:
a. Lift the backplane latch (callout 1).
b. Remove the backplane from the drive cage (callout 2).