3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Do one of the following:
a. Remove the air baffle .
b. Remove the midplane drive cage .
9. If installed, remove the cable guards .
10. Disconnect the riser cable from the system board.
11. Remove the riser cage.
12. Remove the expansion card .
Replacing the stacking riser from the three-slot riser cage
Replacing the stacking riser from the three-slot riser cage
13. Remove all risers from the riser cage.
Retain all screws for future use.