HPE ProLiant DL385 Gen11 Maintenance And Service Manual page 137

Table of Contents

Advertisement

4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. If the server is in the rear 4 LFF drive configuration, remove the rear 4 LFF drive cage .
9. Do one of the following:
a. If removing the type-o controller from Slot 21, remove the primary riser cage .
b. If removing the type-o controller from Slot 22, remove the secondary riser cage.
10. Disconnect the storage cables from the type-o controller.
11. Remove the type-o storage controller:
a. Rotate the locking pin to the open (vertical) position (callout 1).
b. Slide the controller out of the bay (callout 2).
Results
Results
To replace the component, reverse the removal procedure.
Removing the boot device
Removing the
boot device security cover from the NS204i-u + secondary low-profile riser
cage
cage
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. If installed, open the cable management arm.
security cover from the NS204i-u + secondary low-profile riser
HPE ProLiant DL385 Gen11 Server Maintenance and Service Guide
137