Provisioning the external alarms

This section provides installation procedures for the provisioning and
verification of the wiring of cabinet alarms for the Series 800A cabinet.
Software controlled external alarms are factory wired internal alarms and
require no physical connections to be made in the cabinet at the time of
installation.
Customer reserved optional alarms are physically connected to a wire-wrap
block on the breaker interface panel from external sources. The breaker
interface panel (BIP) contains a connectorized wire-wrap block that provides
a location for office connections for customer reserved optional office alarms,
orderwire and parallel telemetry. Reference Chapter 13, "Cabinet and
equipment wiring and cabling" for complete alarm wiring connection
schematics.

How to use this chapter

In the following table, you will find a list of the procedures to provision
external alarms and wire reserved customer alarms for the AccessNode S800A
Outside Plant (OSP) cabinet. Perform the procedures in the order listed. If you
cannot successfully complete these procedures, contact your next level of
support.

Chapter task list

Task
Provisioning and verifying the external
alarms
Wiring customer reserved optional defined
external alarms
AccessNode Series 800A Outside Plant Cabinet Installation 323-3001-210 Issue 1.0
See
Procedure 8-1 on page 8-3
Procedure 8-2 on page 8-5