Nortel SONET AccessNode 800A Series Manual page 166

Outside plant cabinet installation
Table of Contents

Advertisement

6-40 Routing and terminating the VF cables
Procedure 6-8 (continued)
Connecting the outside plant cable pairs to 710 or 3M MS2 DPM connectors without
cross-connect
Table 6-4
Routing binder groups across the swing frame (pair count top to bottom)
Support
bar
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
AccessNode 323-3001-210 Issue 1.0
Table 6-4 (pair count top to bottom) outlines each binder group and its
respective swing frame support bar position.
Column 1
binder group
VF line
Distribution
number
Pairs 601–1200
1–25
White / Blue
26–50
White / Orange
51–75
White / Green
76–96
White / Brown
97–121
White / Slate
122–146
Red / Blue
147–171
Red / Orange
172–192
Red / Green
193–217
Red / Brown
218–242
Red / Slate
243–267
Black / Blue
368–288
Black / Orange
289–313
Black / Green
314–338
Black / Brown
339–363
Black / Slate
364–384
Yellow / Blue
385–409
Yellow / Orange
410–434
Yellow / Green
435–459
Yellow / Brown
460–480
Yellow / Slate
481–505
Violet / Blue
506–530
Violet / Orange
531–555
Violet / Green
556–576
Violet / Brown
—continued—
Column 2
Column 3
SPC cables
binder group
Feeder
Distribution
Pairs 1–600
Pairs 1–600
1–25
White / Blue
26–50
White / Orange
51–75
White / Green
76–100
White / Brown
101–125
White / Slate
126–150
Red / Blue
151–175
Red / Orange
176–200
Red / Green
201–225
Red / Brown
226–250
Red / Slate
251–275
Black / Blue
276–300
Black / Orange
301–325
Black / Green
326–350
Black / Brown
351–375
Black / Slate
376–400
Yellow / Blue
401–425
Yellow / Orange
426–450
Yellow / Green
451–475
Yellow / Brown
476–500
Yellow / Slate
501–525
Violet / Blue
526–550
Violet / Orange
551–575
Violet / Green
576–600
Violet / Brown

Advertisement

Table of Contents
loading