12-4 Cabinet maintenance operations
Table 12-1 (continued)
Recommended maintenance for the Series 800A cabinet
Item
Batteries
Door hinges and pins
Paint finish
System ground
Ground Fault Interrupt
(GFI)
High and low
temperature
sensors
AccessNode 323-3001-210 Issue 1.0
Operation
1) Refer to the battery manufacturer's
suggested procedures or local practices for
routine battery maintenance.
2) Verify battery and cabling by removing the
battery string cable assembly plugs. Remove
the plugs one at a time from the battery breaker
interface connector.
3) Check the battery voltage presence and
value.
4) Reconnect the plug to its assigned location
from which it was removed.
5) Replace batteries or cable assemblies as
required.
Lubricate with either of the two suggested
following materials:
• 3M #8915, white lithium grease, 24 oz.
aerosol spray can (CPC: R0112617)
• American Grease Stick Co. #DKC-3, tan wax
grease stick (CPC: R0115456)
Refer to Table 12-2 for order replacement
information for the Series 800A Brush-on
touch-up paint kit.
1) Check all system ground connections.
2) Measure the ground resistance according to
local approved methods. The ground to each
resistance must be ≤ 25 Ω.
Test GFI for proper operation.
1) For the high temperature sensor, use a heat
gun or hair dryer on the high temperature
sensor and watch for the alarm; the coded
alarm is a major alarm based on customer
assigned alarm provisioning.
2) For the low temperature sensor, use a
cooling/freezing spray on the low temperature
sensor and watch for the alarm; the coded
alarm is a major alarm based on customer
assigned alarm provisioning (see Chapter 8,
"Provisioning the external alarms").
—end—
Recommended Interval
1) 12 months with an average
ambient temperature of 77°
F. Check more often in
warmer climates
2) During routine cabinet
maintenance procedures or
as required by local practices
As required:
Spray liberally.
Use a clean, odorless
applicator.
As required
As required
Follow local codes and test
each time prior to use.
As required