Nortel SONET AccessNode 800A Series Manual page 204

Outside plant cabinet installation
Table of Contents

Advertisement

7-34 Routing and splicing the fiber cable
Procedure 7-4 (continued)
Routing fiber to the ABM when no FPP is installed
Cable entry
The termination compartment has four 4.50-inch inside diameter (ID)
openings for 4.00-inch trade size conduit and one 2.00-inch ID opening for
1.50-inch trade size conduit.
Table 7-7 shows the conduit openings in the termination compartment.
Table 7-7
Termination compartment conduit openings
Opening size
4.50 inches
(11.43 cm)
4.50 inches
(11.43 cm)
4.50 inches
(11.43 cm)
4.50 inches
(11.43 cm)
2.00 inches
(5.08 cm)
Table 7-8 shows where the fiber cabling has been pulled into the termination
compartment (see Chapter 4, "Installing the OSP cables") and how much slack
has been pulled for cable routing.
Table 7-8
OSP cable entry locations and lengths
When you pull cable for
VF cable pairs 1–600
VF cable pairs 601–1200
VF or miscellaneous pairs
T1 distribution or maintenance pairs
Fiber
AccessNode 323-3001-210 Issue 1.0
Note: All trade sizes listed are based on Schedule 40 PVC.
Conduit trade size
4.00 inches
(10.16 cm)
4.00 inches
(10.16 cm)
4.00 inches
(10.16 cm)
4.00 inches
(10.16 cm)
1.50 inches
(3.81 cm)
Function
VF - pairs 1–600 cable entrance
VF - pairs 601–1200 cable entrance
VF - miscellaneous cable entrance
VF - HF or fiber cable entrance
Earth ground rod connection entrance
Into the termination
compartment conduit
opening at this
location
far left
middle left
middle right
middle right
far right
—continued—
Then leave this
number of feet
of cable for
routing
10 ft (3.1 m)
12 ft (3.7 m)
25 ft (7.6 m)
5 ft (1.5 m)
25 ft (7.6 m)