Nortel SONET AccessNode 800A Series Manual page 221

Outside plant cabinet installation
Table of Contents

Advertisement

Procedure 8-2 (continued)
Wiring customer reserved optional defined external alarms
Step
5
6
Figure 8-1
BIP wire-wrap block pin field layout and connections
E2A
receive
E2A
transmit
Orderwire
connections
Office
alarms
AccessNode Series 800A Outside Plant Cabinet Installation 323-3001-210 Issue 1.0
Action
Dress and tie-wrap all installed alarm cabling.
Remove all combustible materials from the cabinet.
PIN #
R01
1
R03
4
R05
7
R07
10
R09
13
R11
16
T15
19
T17
22
OWTIP
25
OWRING OWBUZR
28
CRAUD
31
CRAUDR MJAUDR
34
CRVIS
37
CRVISR
40
Note: For the NT4K14BA BIP the pinfield above is rotated 90˚ clockwise.
Provisioning the external alarms 8-7
RRET
R02
RRET
R04
RRET
R06
RRET
R08
RRET
R10
RRET
RRET
TRET
T16
TRET
T18
OWBUZ
ACOSW
ACOSWR
MJAUD
MNAUD
MNAUDR
MJVIS
MNVIS
MJVISR
MNVIS
—end—
FW-15150
FW-15150
PIN #
3
6
9
12
15
18
21
24
27
30
33
36
39
42