Nortel SONET AccessNode 800A Series Manual page 182

Outside plant cabinet installation
Table of Contents

Advertisement

7-12 Routing and splicing the fiber cable
Procedure 7-1 (continued)
Routing the OSP fiber cable directly to the FPP
Step
9
10
11
Figure 7-6
Butt and ground the fiber cable at the FPP (left rear view)
AccessNode 323-3001-210 Issue 1.0
Action
Measure the length of the fiber cable to establish the point at which the cable
is to be butted.
Note: The cable butt should be 1/2-inch (1.27 cm) above the bonding and
grounding bracket mounted on the FPP (see Figure 7-6).
Butt the fiber cable.
Protect the fibers with buffer tubing as specified by local practices or job
specifications.
Ground lug
OSP fiber cables
Tie-wrap
Swing frame
—continued—
Bonding clamp
Ground wire
FW-15131
FW-15131