7-26 Routing and splicing the fiber cable
Procedure 7-3 (continued)
Routing the OSP fibers in split flex tubing to the FPP
Step
8
Figure 7-12
Routing fiber patch cords to the OC-12 cards
AccessNode 323-3001-210 Issue 1.0
Action
Hang the connector end of the patch cords out of the cable trough to the left
of the tab that is located above the card to which the patch cord connects (see
Figure 7-12).
Cable trough
Fiber patch cord
OC-3 or OC-12
interface card
CAUTION
Risk of damage to fiber patch cords
Ensure that each fiber patch cord exits the cable trough to the left
of the tab that is immediately above the card to which the patch
cord connects. If a cord exits the trough to the right of the tab, it
may snag and become damaged when an adjacent card is
removed.
—continued—
Tab