Table 13-20 shows the SPC to CDS VF cabling and wiring for the
S800A cabinet.
The last four pairs (22–25) in the VF cable from each CDS VF connector
76–96 are not used. Protector block positions 97-100 are unused in S800A
applications.
VF cables NT1W87BD, NT1W87BE and NT1W87BF are used to connect to
the NT4K12AA CDS shelf. VF cables NT1W87BG, NT1W87BH and
NT1W87BJ are used to connect to the NT4K12AB CDS shelf.
Table 13-20
SPC/CDS VF cabling and wiring
From
Location
Terminal
SPC VF-1
P1
SPC VF-1
P2
SPC VF-1
P3
SPC VF-1
P4
SPC VF-2
P5
SPC VF-2
P6
SPC VF-2
P7
SPC VF-2
P8
SPC VF-3
P9
SPC VF-3
P10
SPC VF-3
P11
SPC VF-3
P12
AccessNode Series 800A Outside Plant Cabinet Installation 323-3001-210 Issue 1.0
Cabinet and equipment wiring and cabling 13-77
Identification
CDS 1
(NT1W87BD/BG)
CDS 1
(NT1W87BD/BG)
CDS 1
(NT1W87BD/BG)
CDS 1
(NT1W87BD/BG)
CDS 2
(NT1W87BD/BG)
CDS 2
(NT1W87BD/BG)
CDS 2
(NT1W87BD/BG)
CDS 2
(NT1W87BD/BG)
CDS 3
(NT1W87BD/BG)
CDS 3
(NT1W87BD/BG)
CDS 3
(NT1W87BD/BG)
CDS 3
(NT1W87BD/BG)
—continued—
To
Location
Terminal
SPC 1
Pairs 01–25
SPC 1
Pairs 26–50
SPC 1
Pairs 51–75
SPC 1
Pairs 76–96
SPC 2
Pairs 01–25
SPC 2
Pairs 26–50
SPC 2
Pairs 51–75
SPC 2
Pairs 76–96
SPC 3
Pairs 01–25
SPC 3
Pairs 26–50
SPC 3
Pairs 51–75
SPC 3
Pairs 76–96
VF line
number
01–25
26–50
51–75
76–96
97–121
122–146
147–171
172–192
193–217
218–242
243–267
268–288