5 DATA USED FOR POSITIONING CONTROL
5.7.2 Axis control data
Setting item
Cd.11 Positioning start No.
Cd.12 Axis error reset
Cd.13 Restart command
Cd.14 M code OFF request
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
•
Set the positioning start No.
•
Clears the axis error detection, axis error No., axis warning detection and axis
warning No.
•
When the AD75 axis operation state is "in error occurrence", the error is cleared
and the AD75 is returned to the "waiting" state.
•
When positioning is stopped for any reason (when axis operation state is
"stopped"), set "1" in Cd.13 . Positioning will be carried out again from the
stopped position to the end point of the stopped positioning data.
•
The M code ON signal turns OFF.
5 - 110
Setting details
MELSEC-A