Axis Control Data - Mitsubishi Electric A1SD75P1-S3 User Manual

Positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL

5.7.2 Axis control data

Setting item
Cd.11 Positioning start No.
Cd.12 Axis error reset
Cd.13 Restart command
Cd.14 M code OFF request
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Set the positioning start No.
Clears the axis error detection, axis error No., axis warning detection and axis
warning No.
When the AD75 axis operation state is "in error occurrence", the error is cleared
and the AD75 is returned to the "waiting" state.
When positioning is stopped for any reason (when axis operation state is
"stopped"), set "1" in Cd.13 . Positioning will be carried out again from the
stopped position to the end point of the stopped positioning data.
The M code ON signal turns OFF.