6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Continued from previous page
No.8
Positioning start No.
setting program
No.9
Positioning start signal input program
No.10
Reset program
No.11
JOG operation program
No.12
Manual pulse generator
operation program
Continued on next page
Start details setting program
Refer to section 6.5.2
Start program
Refer to section 6.5.3
Program to reset the start
signal and turn the M code
ON signal OFF
JOG operation program
Refer to section 11.2.4
Manual pulse generator
operation program
Refer to section 11.3.4
6 - 10
MELSEC-A
* Program required to carry out
• "Zero point return control"
• "Main positioning control"
• "Advance d positioning control"
* Program required to carry out
"manual control"