12 CONTROL AUXILIARY FUNCTIONS
(2) Precaution during control
(3) Setting the override function
Setting item
Positioning
Cd.18
operation speed
override
* Refer to section "5.7 List of control data" for details on the setting details.
Positioning start signal
PLC READY signal
AD75 READY signal
Start complete signal
BUSY signal
Positioning complete signal
Error detection signal
Fig. 12.28 Time chart for changing the speed using the override function
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(a) When changing the speed during continuous path control, the speed change
will be ignored if there is not enough distance remaining to carry out the
change.
(b) A warning "deceleration and stop speed change" (warning code: 500)
occurs and the speed cannot be changed in the following cases.
During deceleration by a stop command
During automatic deceleration during positioning control
(c) When the speed is changed during interpolation control, the required speed
is set in the reference axis.
The following shows the data settings and sequence program example for setting
the override value of axis 1 to "200%".
(a) Set the following data. (Use the start time chart shown in section (2) below
as a reference, and set using the sequence program shown in section (3).)
Setting
value
200
Set the new speed as a percentage (%).
(b) The following shows a time chart for changing the speed using the override
function.
V
[Y10]
[Y1D]
[X0]
[X1]
[X4]
[X7]
[XA]
Cd. 18 Positioning operation
speed override
12 - 43
Setting details
200
MELSEC-A
Buffer memory address
Axis 1 Axis 2 Axis 3
1159
1209
1259
Dwell time