12 CONTROL AUXILIARY FUNCTIONS
Carry out a machine zero point return.
Move the workpiece to the circular
interpolation auxiliary point using a
manual operation.
Set the positioning data No. for
which the teaching will be carried out.
Select "Set the current feed value to the
arc auxiliary point ( Da.6 Arc address)"
in the write pattern.
Carry out a writing request.
Confirm the completion of the writing.
Move the workpiece to the circular
interpolation end point position
using a manual operation.
Select "Set the current feed
value to the end point ( Da.5
Positioning address/movement
amount)" in the write pattern.
Carry out a writing request.
II
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(b) When teaching to the " Da.6 Arc address", then teaching to the " Da.5
Positioning address/movement amount"
Start
• • • • • • • •
Set the target axis.
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
I
Using a JOG operation or manual pulse generator.
Set the target axis in the buffer memory address [1103].
Set the positioning data No. in the buffer memory address [1104].
Set 60F
in the buffer memory address [1105].
H
Set 2 in buffer memory address [1106]
Confirm that the buffer memory address [1106] has become 0.
Using a JOG operation or manual pulse generator.
Set 50F
in the buffer memory address [1105].
H
Set 2 in buffer memory address [1106]