Mitsubishi Electric A1SD75P1-S3 User Manual page 248

Positioning module
Table of Contents

Advertisement

6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
V
Start
Positioninig data No. 10
(3) Control data requiring settings
Setting item
Interrupt request
Cd.32
during continuous
operation
* Refer to section "5.7 List of control data" for details on the setting details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(3) If the operation cannot be decelerated to a stop because the remaining
distance is insufficient when "continuous operation interrupt request" is
executed with continuous path control, the interruption of the continuous
operation will be postponed until the positioning data shown below.
Positioning data No. have sufficient remaining distance
Positioning data No. for positioning complete (pattern: 00)
Positioning data No. for continuous positioning control (pattern: 01)
(4) When operation is not performed (BUSY signals [X4, X5, X6] are OFF), the
continuous operation interrupt request is not accepted. It is cleared to zero at a
start or at a restart.
Even when the continuous operation interrupt is requested,
the remaining distance is insufficient, and thus, the
operation cannot stop at the positioning No. being executed.
Continuous operation
interrupt request
Positioning data No. 11
Set the following data to interrupt continuous operation.
Setting
value
Set "1: Interrupt request during continuous
1
operation".
Stop process when operation cannot stop
at positioning data No.10
Positioning data No. 12
Setting details
6 - 32
MELSEC-A
t
Buffer memory address
Axis 1 Axis 2 Axis 3
1181
1231
1281

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3