Mitsubishi Electric A1SD75P1-S3 User Manual page 429

Positioning module
Table of Contents

Advertisement

12 CONTROL AUXILIARY FUNCTIONS
(2) Precautions during control
(3) Setting the speed limit function
Setting item
Pr.7
Speed limit value
JOG speed limit
Pr.32
value
* Refer to section "5.2 List of parameters" for setting details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
During interpolation control, speed limiting is carried out at the reference axis
side setting value.
(The speed limit will not function on the interpolation side.)
To use the "speed limit function", set the "speed limit value" in the parameters
shown in the following table, and write them to the AD75.
The set details are validated after they are written to the AD75.
Setting
value
Set the speed limit value (max. speed during control).
Set the speed limit value during JOG operation (max.
speed during control). (Note that " Pr.32 JOG speed
limit value" shall be less than or equal to " Pr.7
Speed limit value".)
REMARK
Parameters are set for each axis.
It is recommended that the parameters be set whenever possible with the AD75
software package. Execution by sequence program uses many sequence
programs and devices. The execution becomes complicated, and the scan times
will increase.
Setting details
12 - 23
MELSEC-A
Factory-set
initial value
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3

Table of Contents