5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.22 Manual pulse generator
enable flag
Cd.23 Manual pulse generator 1
pulse input magnification
Cd.24 Zero point return request flag
OFF request
Cd.25 External start valid
Cd.26 Step valid flag
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Set whether or not to carry out manual pulse generator operation.
Set the magnification of the No. of pulses input from the manual pulse generator.
When setting value is 0 or less: Processed as "1"
When setting value is 101 or more: Processed as "100"
When the zero point return request flag is ON, set the request to turn this OFF
forcibly with the sequence program.
Set whether external starting is valid.
Set whether to carry out step operation.
5 - 116
Setting details
MELSEC-A