5 DATA USED FOR POSITIONING CONTROL
Da.14 Condition target
01
02
03
04
05
Da.15 Condition operator
Da.14 Condition target
01
:
Device X
H
02
:
Device Y
H
03
:
Buffer memory (1-word)
H
04
:
Buffer memory (2-word)
H
05
:
Positioning data No.
H
Da.16 Address
Da.14 Condition target
01
: Device X
H
02
: Device Y
H
03
: Buffer memory (1-word)
H
04
: Buffer memory (2-word)
H
05
: Positioning data No.
H
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Set the condition target as required for each control.
Setting value
: Device X
H
: Device Y
H
: Buffer memory (1-word)
H
: Buffer memory (2-word)
H
: Positioning data No.
H
Set the condition operator as required for the " Da.14 Condition target".
Setting value
07
: DEV=ON
H
08
: DEV=OFF
H
: ∗∗=P1
01
H
: ∗∗≤P1, P2≤∗∗
06
H
09
: Axis 1 designation
H
0E
: Axis 2 and axis 3
H
designation
Set the address as required for the " Da.14 Condition target".
Setting value
Value
(Buffer memory address)
Setting details
Set the input/output signal ON/OFF as the conditions.
Set the value stored in the buffer memory as the condition.
03
: The target buffer memory is "1-word (16 bits)"
H
04
: The target buffer memory is "2-word (32 bits)"
H
Select only for "simultaneous start".
When the input/output signal ON/OFF is set as the
condition, set "ON" or "OFF".
Set how to judge the conditions for the value (∗∗)
target stored in the buffer memory.
Set the axis to start simultaneously when
"simultaneous start" is selected.
Not used. (There is no need to set.)
Set the target "buffer memory address".
(For 2 word, set the low-order buffer memory
address.)
Not used. (There is no need to set.)
5 - 78
MELSEC-A
Setting details
Setting details

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3

Table of Contents