Storage item
Md.29 Current feed value
Md.30 Machine feed value
Md.31 Feedrate
Md.32 Valid M code
Md.33 Axis error No.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The currently commanded address is stored. (Different from the actual motor
position during operation)
The current position address is stored.
Update timing : 56.8ms
The zero point address is stored when the machine zero point return is
completed.
When the current value is changed with the current value charge function, the
changed value is stored.
The address of the current position obtained with the machine coordinates is
stored. (Different from the actual motor position during operation)
Machine coordinates: Characteristic coordinates determined with machine
Update timing: 56.8ms
The speed commanded by the AD75 is stored.
(May be different from the actual motor position during operation)
During interpolation operation, the speed is stored in the following manner.
Reference axis
: Composite speed or reference axis speed
(Set with Pr.21 )
Interpolation axis : 0
Update timing: 56.8ms
The currently valid M code (set in the positioning data currently operating) is
stored.
Update timing : When M code ON signal turns ON
When an axis error is detected, the error code corresponding to the error details is
stored.
The latest error code is always stored.
(When a new axis error occurs, the error code is overwritten.)
When "axis error reset" (axis control data) turns ON, the axis error No. is
cleared (set to 0).