Mitsubishi Electric AJ65VBTCU-68ADVN User Manual

Mitsubishi Electric AJ65VBTCU-68ADVN User Manual

Analog-digital converter module

Advertisement

Quick Links

Converter Module
AJ65VBTCU-68ADVN/ADIN
Thank you for buying the programmable controller MELSEC Series
Prior to use, please read both this manual and detailed manual
thoroughly and familiarize yourself with the product.
© 2003 MITSUBISHI ELECTRIC CORPORATION
Analog-Digital
MODEL AJ65V-68ADN-U-HW
MODEL
CODE
IB(NA)-0800251-H(1612)MEE
User's Manual
(Hardware)
13JP19

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric AJ65VBTCU-68ADVN

  • Page 1 (Hardware) AJ65VBTCU-68ADVN/ADIN Thank you for buying the programmable controller MELSEC Series Prior to use, please read both this manual and detailed manual thoroughly and familiarize yourself with the product. MODEL AJ65V-68ADN-U-HW MODEL 13JP19 CODE IB(NA)-0800251-H(1612)MEE © 2003 MITSUBISHI ELECTRIC CORPORATION...
  • Page 2 SAFETY PRECAUTIONS (Read these precautions before using this product.) Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly. These precautions apply only to this equipment. Refer to the user 's manual of the CPU module to use for a description of the programmable controller system safety precautions.
  • Page 3 [Design Precautions] CAUTION ● Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm (3.94 inches) or more between them. Failure to do so may result in malfunction due to noise. [Installation Precautions] CAUTION ●...
  • Page 4 [Wiring Precautions] CAUTION ● Shut off the external power supply for the system in all phases before wiring. Failure to do so may result in damage to the product. ● Ground the FG pin and FG1 pin to the protective ground conductor dedicated to the programmable controller.
  • Page 5 [Wiring Precautions] CAUTION ● Smoke and fire may occur when an overcurrent flows intermittently for a long period of time. To avoid this, configure a safety circuit, such as an external fuse, to protect the product. [Starting and Maintenance Precautions] CAUTION ●...
  • Page 6 PRÉCAUTIONS DE SÉCURITÉ (Lire ces précautions avant toute utilisation du produit.) Avant d'utiliser ce produit, lire attentivement ce manuel ainsi que les manuels auxquels il renvoie, et toujours considérer la sécurité comme de la plus haute importance en manipulant le produit correctement. Ces précautions ne concernent que cet équipement.
  • Page 7 [Précautions lors de la conception] ATTENTION ● Ne pas entremêler les lignes de commandes ou câbles de communication avec les lignes des circuits principaux ou les câbles d'alimentation. Les installer en maintenant entre eux une distance minimum de 100mm (3,94 pouces).
  • Page 8 [Pécautions de câblage] ATTENTION ● Couper l'alimentation externe du système sur toutes les phases avant de commencer à câbler. Faute quoi, le produit risquerait d'être endommagé. ● Mettez à la terre la broche FG et la broche de FG1 au conducteur de protection à...
  • Page 9 [Pécautions de câblage] ATTENTION ● Des surtensions intermittentes qui se prolongent dans le temps peuvent être à l'origine d'un dégagement de fumée et d'un départ de feu. Pour éviter cela, prévoir un circuit de sécurité, avec fusible externe par exemple, pour protéger le produit.
  • Page 10 CONDITIONS OF USE FOR THE PRODUCT (1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions; i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
  • Page 11 Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or other safety features which exceed the general specifications of the PRODUCTs are required.
  • Page 12 Section 6.2, Chapter 8 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 13: Table Of Contents

    CONTENTS 1. OVERVIEW ....................1 2. SPECIFICATION .................... 2 Performance specifications ..............2 3. NAMES AND SETTING OF PARTS............... 5 4. LOADING AND INSTALLATION ..............9 Precautions when handling ..............9 Installation environment ................ 9 5. DATA LINK CABLE WIRING ................ 10 Connection of the CC-Link dedicated cables ........
  • Page 14 The following manuals are also related to this product. In necessary, order them by quoting the details in the tables below. Detailed Manual Manual number Manual name (Model code) Analog-Digital Converter Module type AJ65VBTCU-68ADVN/ADIN SH-080401E User's Manual (13JR65) Related Manual Manual number...
  • Page 15: Overview

    1. OVERVIEW This user's manual explains the specifications, names and setting of parts, wiring and others of Type AJ65VBTCU-68ADVN analog-digital converter module (hereafter abbreviated to the "AJ65VBTCU- 68ADVN") and Type AJ65VBTCU-68ADIN analog-digital converter module (hereafter abbreviated to the "AJ65VBTCU-68ADIN") which is used as a remote device station of a CC-Link system.
  • Page 16: Specification

    2. SPECIFICATION Performance specifications The performance specifications of the AJ65VBTCU-68ADVN/ADIN are shown below. For general specifications, refer to detailed manual. Item AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN Protection class IP1XB -10 to 0 to 10V DC Voltage (input resistance 1M) Analog input 0 to +20mA DC Current (input resistance 250)
  • Page 17 Item AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN Insulation Dielectric Insulation Insulated area method withstand voltage resistance Across communication 5M or higher, system terminals and all Photocoupler measured with analog input terminals Insulation 500VAC for 1 500VDC minute Across power supply insulation system terminals and all...
  • Page 18 Item AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN 24VDC (20.4 to 26.4VDC, ripple factor within 5%) External power supply Inrush current: 4.2A, within 1.2ms Current consumption: 0.10A (When 24VDC) Weight 0.17kg *1: digit indicates digital value. *2: Current value indicates value of instant input current that does not break module inner electrical resistance.
  • Page 19: Names And Setting Of Parts

    3. NAMES AND SETTING OF PARTS The name of each part in the AJ65VBTCU-68ADVN/ADIN is shown. [Pin layout and signals name] Pin arrangement Pin No. Signal name CONA,B CH V+/I+ CH V-/I- CONA CON1 to 8 CONB CON1 CON2 +24V (UNIT)
  • Page 20 Name and Description appearance : Power supply on POWER OFF : Power supply off : Normal operation Flickering: 0.1s intervals: Input range setting error, mode select switch setting error. This module is used as the Ver.2 remote device station Normal (Ver.2 compatible slave station) when the network mode parameter mode is set to remote network Ver.1 mode.
  • Page 21 Name and Description appearance The switch to be used for selecting the mode among Ver. remote device station (Ver. -compatible slave station)/Normal mode/Test mode AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN Ver.1 remote 0: Normal mode Ver.1 remote 0: Normal mode device station 1: Test mode...
  • Page 22 Name and Description appearance Use the switches in STATION NO. "10", "20" and "40" to set the tens of the station number. Use the switches in STATION NO. "1", "2", "4" and "8" to set the units of the station number.
  • Page 23: Loading And Installation

    4. LOADING AND INSTALLATION Precautions when handling The following is an explanation of handling precautions of the module. (1) Because the case of the module is made of resin, be careful not to drop it or expose it to strong impact. Installation environment Never install the module in the following environments: (1) Locations where the ambient temperature is outside the range of 0...
  • Page 24: Data Link Cable Wiring

    Connection of the CC-Link dedicated cables Raccordement des câbles dédiés CC-Link Connect the CC-Link dedicated cable between the AJ65VBTCU- 68ADVN/ADIN and master module as shown below. Raccorder le câble dédié CC-Link entre AJ65VBTCU-68ADVN/ADIN et le module maître comme illustré ci-dessous. One-touch connector plug for communication...
  • Page 25 [CC-Link dedicated cable wiring diagram] Online connector Online connector for communication for communication Master module Terminating CONA CONA (Blue) (Blue) resistor (White) (White) (Yellow) (Yellow) (Blue) (White) CONB CONB (Blue) (Yellow) (White) (Yellow) Terminating resistor (A6CON-TR11(N)) Ver.1.10 Compatible CC-Link dedicated cable (FANC-110SBH,CS-110,FA-CBL200PSBH) English French One-touch connector plug for...
  • Page 26 English French Ver.1.10 Compatible CC-Link dedicated cable Câble dédié CC-Link compatible Ver.1.10 (FANC-110SBH,CS-110,FA-CBL200PSBH) (FANC-110SBH,CS-110,FA-CBL200PSBH) Point • On this unit, use the Ver. 1.10-compatible CC-Link dedicated cable (FANC-110SBH, CS-110, FA-CBL200PSBH). You cannot use the Ver. 1.10-compatible CC-Link dedicated cables of other than the above types, CC-Link dedicated cables and CC-Link dedicated, high-performance cables.
  • Page 27: Wiring

    The precautions when performing external wiring are as follows: Pour obtenir les meilleures performances des fonctionnalités du AJ65VBTCU-68ADVN/ADIN et améliorer la fiabilité du système, il est important que le câblage soit durablement résistant aux interférences. Les précautions suivantes doivent être observées lors de de l'exécution du câblage externe.
  • Page 28 (4) Smoke and fire may occur when an overcurrent flows intermittently for a long period of time. To avoid this, configure a safety circuit, such as an external fuse, to protect the product. Des surtensions intermittentes qui se prolongent dans le temps peuvent être à...
  • Page 29: Wiring Of Module With External Equipment

    Wiring of module with external equipment (1) AJ65VBTCU-68ADVN (For voltage input) AJ65VBTCU-68ADVN (Pour entrée de tension) Signal souce 0 to CON1 CH.1 500k CH.1 V+ CH.1 V- 500k *1 Shield CON8 CH.8 500k CH.8 V+ CH.8 V- 500k *1 Shield (2) AJ65VBTCU-68ADIN (For current input) AJ65VBTCU-68ADIN (Pour entrée de courant)
  • Page 30 Point • Do not insert the one-touch connector plug for I/O of the one-touch connector type/connector type compact remote I/O unit into the one- touch connector for analog I/O accidentally. Doing so can cause the module to be damaged. • In an unused channel, if terminals remain open, an erratic digital value may be output.
  • Page 31: How To Wire The One-Touch Connector Plug

    One-touch connector plug for analog crimping sleeves I/O Connect the applicable cable (*1). Example: Butt joint *1: For the applicable cable size, refer to the AJ65VBTCU-68ADVN/ADIN Analog-Digital User's Manual. Point • Where possible, round the tip that was cut with nippers or like.
  • Page 32 (2) Check the plug cover Check that the plug cover is attached to in the plug. Note: Plug cover Do not push the plug cover into the plug body. Plug body Once pressed, the plug cannot be used any more. Metal contact (3) Insert the cable Lift the end of the plug cover and insert the cable...
  • Page 33: External Dimension Diagram

    8. EXTERNAL DIMENSION DIAGRAM [AJ65VBTCU-68ADVN/ADIN] 31 (1.22) 67 (2.64) 41 (1.61) (0.14) 16.5 (0.65) *: This section should be 14.5mm (0.57inch) when an online connector is not installed. Unit: mm (inch)
  • Page 34 20 Waterford Office Park, 189 Witkoppen Road, Avenida Adelino Cardana, 293, 21 andar, Fourways, South Africa Bethaville, Barueri SP, Brazil Tel : +27-11-658-8100 Tel : +55-11-4689-3000 Germany MITSUBISHI ELECTRIC EUROPE B.V. German China MITSUBISHI ELECTRIC AUTOMATION (CHINA) Branch LTD. Mitsubishi-Electric-Platz 1, 40882 Ratingen, No.1386 Hongqiao Road, Mitsubishi Electric...

This manual is also suitable for:

Aj65vbtcu-68adin

Table of Contents