Mitsubishi Electric A1SD75P1-S3 User Manual page 533

Positioning module
Table of Contents

Advertisement

14 TROUBLESHOOTING
Relevant buffer memory address
Axis 1
Axis 2
Axis 3
74
224
374
75
225
375
76
226
376
77
227
377
78
228
378
86
236
386
80
230
380
81
231
381
82
232
382
83
233
383
88
238
388
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting range
(Setting given in sequence program)
(In standard mode)
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
(In stepping motor mode)
1 to 62500 [pulse/s]
1 to 37500000 [mm/min, etc.]
(In standard mode)
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
(In stepping motor mode)
1 to 62500 [pulse/s]
1 to 37500000 [mm/min, etc.]
0, 1
1 to 300
(In standard mode)
0 to 2147483647
(In stepping motor mode)
0 to 134217727
0, 1, 2 ,3
0, 1, 2 ,3
0, 1
14 - 29
Remedy
Change the setting to within the setting range and turn
OFF then ON the PLC READY signal (Y1D).
• Write the flash ROM again.
• If the same error persists, replace the module.
MELSEC-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3