Mitsubishi Electric A1SD75P1-S3 User Manual page 171

Positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Item
Value set with peripheral
01 : Device X
02 : Device Y
Da.14
03 : Buffer memory (1-word)
Condition
target
04 : Buffer memory (2-word)
05 : Positioning data No.
01 : ∗∗=P1
02 : ∗∗ ≠ P1
03 : ∗∗≤P1
04 : ∗∗≥P1
05 : P1≤∗∗≤ P2
06 : ∗∗≤P1, P2≤∗∗
07 : DEV=ON
Da.15
08 : DEV=OFF
Condition
09 : Axis 1 designation
operator
0A : Axis 2 designation
0B : Axis 1 and axis 2
designation
0C : Axis 3 designation
0D: Axis 1 and axis 3
designation
0E : Axis 2 and axis 3
designation
Da.16 Address Buffer memory address
Da.17
Value
Parameter 1
Da.18
Value
Parameter 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting value
Value set with sequence program
device
01
H
02
H
03
H
04
H
05
H
01
H
02
H
03
H
04
H
05
H
06
H
07
H
08
H
09
H
0A
H
0B
H
0C
H
0D
H
0E
H
Example)
(High-order)
b31
Example)
(High-order)
b31
Example)
(High-order)
b31
5 - 77
Condition target
Condition operator
b15
b8
b7
b0
4493
4492
(Low-order)
b16
b15
Buffer memory address
4495
4494
(Low-order)
b16
b15
Value
4496
4497
(Low-order)
b16
b15
Value
MELSEC-A
Setting value buffer
memory address
Default
value
Axis 1 Axis 2 Axis 3
0000
4490 4740 4990
H
4492
4742
4992
b0
0000
H
4493
4743
4993
4494
4744
4994
b0
0000
H
4495
4745
4995
4496
4746
4996
b0
0000
H
4497
4747
4997

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3

Table of Contents