12 CONTROL AUXILIARY FUNCTIONS

12.6.8 Indirectly specification function

The "indirectly specification function" specifies indirectly and starts the positioning data
No.
The "indirectly specification function" is executed by setting the positioning data No. 1
to 600 desired to be started to the "indirectly specification data area" and starting that
"indirectly specification data".
The "indirectly specification data" can be set on an "indirectly specification No. (8001 to
8050)" basis and can be set to up to 50 pieces on an axis basis.
The following details will be explained about the "indirectly specification function".
(1) "Indirectly specification data" setting items and setting details
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(1) "Indirectly specification data" setting items and setting details
(2) "Indirectly specification data" configuration
(3) Control details and setting
The following indicates the outline of the setting items and setting details of the
"indirectly specification data" to be stored into the AD75.
Setting item
Positioning data No. for
indirectly specification
No. 8001
Positioning data No. for
indirectly specification
No. 8002
Positioning data No. for
indirectly specification
No. 8003
Positioning data No. for
indirectly specification
No. 8004
Positioning data No. for
indirectly specification
No. 8005
to
Positioning data No. for
indirectly specification
No. 8046
Positioning data No. for
indirectly specification
No. 8047
Positioning data No. for
indirectly specification
No. 8048
Positioning data No. for
indirectly specification
No. 8049
Positioning data No. for
indirectly specification
No. 8050
Setting details
Set the positioning data No. (1 to 600) whose execution will be
started when 8001 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8002 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8003 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8004 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8005 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8046 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8047 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8048 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8049 is set as the positioning start No. and
started.
Set the positioning data No. (1 to 600) whose execution will be
started when 8050 is set as the positioning start No. and
started.
12 - 82