12 CONTROL AUXILIARY FUNCTIONS
MELSEC-A
(3) Setting the torque change function start signal
To use the "torque change function", write the data shown in the following table
to the AD75 using the sequence program.
The set details are validated when written to the AD75.
Buffer memory address
Setting
Setting item
Setting details
value
Axis 1 Axis 2 Axis 3
Cd.30
New torque value
Set the new torque limit value.
1176
1226
1276
* Refer to section "5.7 List of control data" for details on the setting details.
12 - 49