4 INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT
(2) Connecting the connector and wire
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
* Refer to section "3.5 Specifications of input/output interfaces with external
devices" when connecting.
(a) Loosen the cable fixture screw B, pass the cable through, and
then tighten screw B.
(Screw B may be removed once, and then tightened after sandwiching the
cable.)
(Take care not to lose the screw and nut.)
Pass the cable through
(b) Solder the wire onto the connector.
Connector pin layout
* The applicable size of the wire to be connected is "AWG#24 to #30
(approx. 0.05 to 0.2SQ)".
4 - 14
B
Cable fixture
Connector
Solder
Wire