F11.31
Keyboard potentiometer lower
(0x0B1F)
limit voltage
RUN
F11.32
Keyboard potentiometer lower
(0x0B20)
limit corresponding value
RUN
F11.33
Keyboard potentiometer upper
(0x0B21)
limit voltage
RUN
F11.34
Keyboard potentiometer upper
(0x0B22)
limit corresponding value
RUN
F11.35
(0x0B23)
Keyboard potentiometer selection
STOP
10.16 Group F12: Communication Parameters
F12.0x group: MODBUS slave parameters
Parameter
(address)
Name
djustable attribute
F12.00
(0x0C00)
Master-slave choice
STOP
F12.01
(0x0C01)
Modbus communication address
STOP
F12.02
Communication
(0x0C02)
selection
STOP
F12.03
(0x0C03)
Modbus data format
STOP
F12.04
Modbus transmission response
(0x0C04)
processing
RUN
F12.05
Modbus communication response
(0x0C05)
delay
RUN
F12.06
Modbus communication timeout
(0x0C06)
failure time
RUN
V/F SVC
V/F SVC
V/F SVC
V/F SVC
V/F SVC
Set the keypad potentiometer channel.
0: Internal keyboard potentiometer
1: External keyboard potentiometer
Content
V/F SVC
0: Slave
1: Host
V/F SVC
V/F SVC
0: 1200 bps
1: 2400 bps
baud
rate
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
V/F SVC
0: (N, 8, 1) no parity,
Data bits: 8,
Stop position: 1
1: (E, 8, 1) even parity,
Data bits: 8,
Stop position: 1
2: (O, 8, 1) odd parity,
Data bits: 8,
Stop position: 1
3: (N, 8, 2) no parity,
Data bits: 8,
Stop position: 2
4: (E, 8, 2) even parity,
Data bits: 8,
Stop position: 2
5: (O, 8, 2) odd parity,
Data bits: 8,
Stop position: 2
V/F SVC
0: The writing operation has a response
1: The writeing operation has no response
V/F SVC
V/F SVC
89
0.50v
(0.00-3.00v)
0.00%
(0.00-100.00%)
2.80v
(0.00-3.00v)
100.0%
(0.00-100.00%)
(0~1)
Factory default
(setting range)
0
(0 ~ 1)
1
(1 ~ 247)
3
(0 ~ 6)
0
(0 ~ 5)
0
(0 ~ 1)
0ms
(0 ~ 500ms)
1.0s
(0.1 ~ 100s)