Download Print this page

Veichi AC10 Series Technical Manual page 110

Advertisement

Parameter details
F14.11 multi-speed 12
F14.12 multi-speed 13
F14.13 multi-speed 14
F14.14 multi-speed 15
F07.30 jog frequency
F01.02~F01.03: Frequency reference source A
Code
Name
(Addr.)
F01.02
(0x0102)
Frequency reference source A
RUN
F01.03
Frequency reference source A
(0x0103)
gain
STOP
Frequency given source A output mode:
0: Keyboard number setting
1: keyboard potentiometer
2: voltage / current analog AI given
3: Reserved
4: Reserved
5: terminal pulse PUL
6: RS485 communication
7: Terminal UP/DW control
8: PID control
9: Program Control (PLC)
10: Reserved
11: Multi-speed speed given
F01.04~F01.06: Frequency reference source B
Code
Name
(Addr.)
F01.04
(0x0102)
Frequency reference source B
RUN
F01.05
(0x0103)
Frequency reference source B gain
STOP
F01.06
Frequency reference source B reference
(0x0106)
value
RUN
Frequency reference source B output mode:
0: Keyboard number setting
1: keyboard potentiometer
2: Voltage/current analog AI given
3: Reserved
4: Reserved
5: terminal pulse PUL
6: RS485 communication
7: Terminal UP/DW control
8: PID control
9: Program Control (PLC)
10: Reserved
11: Multi-speed speed given
Frequency reference source B reference value:
0: Reference source F01.10 [maximum frequency]
1: Reference source is set by frequency reference source A
F01.07: Frequency reference source combination selection
Code
Name
(Addr.)
F01.07
Frequency given source combination
(0x0107)
selection
RUN
0: frequency reference source A
1: Frequency reference source B
2: the sum of the frequency given source A and the frequency given source B
AC10 Series Frequency Inverter Technical Manual
OFF
OFF
ON
OFF
OFF
ON
ON
ON
-
-
Content
V/F SVC
Select a given frequency input method
V/F SVC
Proportional gain processing for a given source A input value
Content
V/F SVC
Select a given frequency input method
V/F SVC
Proportional gain processing for a given source B input value
V/F SVC
The source B input value is linearized and the input value is
100%.
Content
V/F SVC
Set the frequency given source A, B combination mode
ON
ON
ON
ON
-
106
ON
OFF
ON
OFF
ON
OFF
ON
OFF
-
ON
Factory setting
(Setting range)
0
(0 ~ 11)
100.0%
(0.0 ~ 500.0%)
Factory setting
(Setting range)
0
(0 ~ 11)
100.0%
(0.0 ~ 500.0%)
0
(0 ~ 1)
Factory setting
(Setting range)
0
(0 ~ 5)